AGG SEALER 888
AGG Sealer 888 is a heavy duty, high solids, solvent based acrylic sealer. AGG 888 enhances the natural colors of stone, while producing a durable, stain resistant barrier. AGG 888 is specially formulated to efficiently seal rough or porous surfaces such as Mexican Saltillo, deep wire-cut brick pavers, exposed aggregate, or any other rough or porous cementitious tiles or materials.
Surfaces treated with AGG 888 with have an enhanced look with a glossy finish. AGG 888 will help stone surfaces resist fading or discoloring from UV rays and will maintain gloss for long periods of time when applied to exterior surfaces. The level of gloss will increase as additional coats are added. For interior or exterior use.
SHOP AGG 888
SURFACES WHERE AGG 888 EXCELS:
Mexican Saltillo
Pavers
Brick
Exposed Aggregate
Rough Stone
Concrete Pavers
Concrete Driveways
SURFACE PREPARATION:
Always be sure the surface is clean, dry, and free from any dirt, grease, oil, wax, or other contaminants. Read the entire label before using. Use only as directed. Always test on a small piece of material or a small inconspicuous area to determine suitability. Ensure the area is well ventilated. Ideal surface temperature should be between 60°F and 80°F. Product works best when it is the first substance applied to the surface, insuring proper penetration.
COVERAGE:
For very porous surfaces: 1st coat: 75-150 sq. ft./gallon. 2nd coat 250-400 sq. ft./gallon. 3rd coat 500+ sq. ft./gallon.
For average density surfaces: 1st coat: 200-300 sq. ft./gallon. 2nd coat 400-500 sq. ft./gallon.
For very dense surfaces: 1000 sq. ft./gallon. Allow 24 hours between coats.
APPLICATION:
PAVERS: Apply with a solvent resistant paint roller having a 1/4 to 3/8-inch nap. Saturate paint roller and remove excess to prevent dripping. Roll sealer liberally, evenly, smoothly, and uniformly. Allow 12 hours to dry. One medium/heavy coat may be sufficient. Additional coats can be applied to increase gloss or even appearance.
MEXICAN SALTILLO TILE:
NEW INSTALLATIONS- BEFORE & AFTER GROUTING: Apply with a solvent resistant paint roller having a 1/4 to 3/8-inch nap. Saturate paint roller and remove excess to prevent dripping. Apply one medium/heavy coat before grouting after tiles have been laid in place and set firmly. Roll on sealer liberally, evenly, smoothly, and uniformly. Do not leave voids and puddles. Work in small areas at a time. Let the sealer dry 12-24 hours before grouting. Clean grout and let surface dry 3-4 days to make sure the grout joints are dry before applying a second coat of sealer. Allow second coat to dry a minimum of 12 hours before applying a third coat if necessary. Gloss will increase as additional coats are added.
RE-APPLICATION: Remove any floor finish on the surface, and clean thoroughly. Allow 12 hours to dry before sealing. Apply with a solvent resistant paint roller having a 1/4 to 3/8-inch nap. Saturate paint roller and remove excess to prevent dripping. Apply one light coat and allow 12 hours to dry. Additional coats can be added if necessary, to add gloss or even appearance. After the sealer is dry, Top Kote Floor Finish can be added to give the floor a glossy finish and protect the sealer.
WIRE CUT BRICK PAVERS: Before grouting, apply a medium coat of sealer with a paint roller having a ¼ inch nap to help protect the tiles from sticking grout. Roll on sealer liberally, evenly, smoothly, and uniformly. Do not leave voids and puddles. Work in small areas at a time. Let the sealer dry 8-24 hours before grouting. Clean grout and let surface dry thoroughly(2-3 days) before applying a second coat in order to seal grout joint.
EXPOSED AGGREGATE: Apply one heavy coat with a ½ to ¾ inch nap paint roller. Let dry. Usually one heavy coat applied properly is sufficient.
STONE: For best results apply with hair bristle paint brush
CLEANUP
Xylene or similar solvent can be used to clean tools.
STORAGE AND HANDLING
CAUTION: Highly flammable & combustible liquid and vapor. Do not handle until all safety precautions have been read and understood. Handling: Do not get in eyes, on skin, or on clothing. Do not breathe vapors or mists. Keep container closed and tightly sealed when not in use. Keep away from sources of ignition - No smoking. Take measures to prevent the buildup of electrostatic charge. Conditions for safe storage: Keep in tightly closed, properly labeled containers. Keep in a cool, well-ventilated place. Materials to avoid: Do not store with the following product types: Strong oxidizing agents, Explosives, Gases.
TECHNICAL SUPPORT
Technical Support is available by calling (813) 876-5914
Emergency Support: ChemTel: 1 (800) 255-3924
BY MAIL: Catalina Chemical Co. 4709 N. Lois Ave. Tampa, FL 33614
TRANSPORTATION
UN number: UN1139
UN proper shipping name: Coating Solution
Transport hazard class: 3
Packing group: 3
PACKAGING
Available in: 1 quart, 1 gallon, 5 gallon, or 55 gallon drum quantities